# Configuration notes for S1 # for more info see: # "Detector Description and Performance for the First Coincidence # Observations Between LIGO and GEO", Nuclear Instruments and Methods # in Physics Research A, Vol. 517/1-3, pp. 154-179 (2004) # Optical configuration Power-recycled Michelson Interferometer with folded arms # Laser powers [approximate] laser power into MC1 = 2 W laser power incident on MPR = 1 W laser power at BS = 270 W # Notes Transmission MPR = 1.3% MSR not installed Main test masses suspended via wire sling triple pendulums